Pipeline AncillariesIn order to guarantee the efficiency of a distribution system and fluid control, several accessories are required but often neglected. Valsteam Adca produces filters, sight glasses, vacuum breakers, drip traps for compressed air systems, air eliminators and several other ancillary items which are vital to the functioning of your installation. To get more information please expand the product block by pressing on image or product title. To get detailed information about specific product you can download Technical datasheet file by clicking corresponding link. Compressed Air Float TrapsA fully automatic ball float trap extremely compact in dimension and light in weight, specially designed for draining water from compressed air lines. FA Series | | | Designed for applications on aftercoolers, separators and compressed air mains. |
Connections are screwed or flanged. Highlights - Modulating discharge
- Unaffected by sudden or wide load and pressure changes
Model | Options | Use | Size | Connections | FA17G | Horizontal reversible inlet connections | Compressed air and non corrosive gas, compatible with the construction | DN ½" - 3/4"; DN 15 - DN 20 or DN 11/2" -2"; DN 40 - DN 50 | Female screwed ISO 7/1 Rp (BS21); Flanged EN 1092-2 PN16 or ANSI | FA20 | Internal strainer (only on horizontal models); Equalizing and drain plug on body; Lifting lever | Compressed air and non corrosive gas compatible with the construction | DN 1/2" - 1", DN 15 - DN 25 | Female screwed ISO 7/1Rp(BS21); Flanged EN 1092-1 PN40 or ANSI | FA32 | Internal strainer (only on horizontal models); Equalizing and drain plug on body; Lifting lever | Compressed air and non corrosive gas compatible with the construction | DN 1" - DN 25 | Female screwed ISO 7/1Rp(BS21); Flanged EN 1092-1 PN40 or ANSI | FA16SS | Compression fitting; Hand purging valve | Cold and hot water systems | DN 1/2" and ¾" | Inlet ½" or ¾" vertical (top to bottom); Outlet ½" vertical; Female screwed ISO 7/1Rp(BS21) | FA21SS | Internal strainer (only on horizontal models); Equalizing and drain plug on body; Lifting lever | Compressed air and non corrosive gas compatible with the construction | DN 1/2" - 1", DN 15 - DN 25 | Female screwed ISO 7/1Rp(BS21); Flanged EN 1092-1 PN40 or ANSI |
Techical datasheet : FA17G (DN 15-20).pdf
| | | | |
Compressed Air Automatic Drain ValveCAD consists of a solid-state timer coupled to a solenoid valve. CAD | | | The CAD is specially designed for automatic draining of filters, separators, aftercoolers, dryers, receivers, drip legs and other compressed air system components where condensate and contaminants collect. |
The draining interval and discharge time can be adjusted according to the requirements. Valve connections are female screwed. Highlights - Easy to read and set time for on/off periods
- Adjustable interval and discharge times
- Manual test switch
- Simple to install
Techical datasheet : CAD (DN 10-20).pdf
| | | | |
Air EliminatorsAir eliminator removes air from water systems. It is also suitable for non corrosive and/or dangerous liquids providing that their specific weight is not less than 0,75Kg/dm3. AE Series | | | This ball float type automatic air eliminator can be used in combination with other air elimination and separation systems or directly applied at high points in the piping. Connections are female screwed or flanged for horizontal or vertical installation. |
Highlights - Corrosion resistant working parts
- Replaceable internal parts
Model | Use | Size | Connections | AE16 | Cold and hot water systems | DN ½", 3/4" and 1" | Inlet ½" to 1" vertical; Outlet ½" vertical; Female screwed ISO 7/1Rp(BS21) | AE16SS | Cold and hot water systems | DN 1/2" and ¾" | Inlet ½" or ¾" vertical; Outlet ½" vertical; Female screwed ISO 7/1Rp(BS21) | AE20 | Cold, hot and superheated water systems | DN ½" - 1", DN 15 to DN25 | Female screwed ISO 7/1Rp(BS21); Flanged EN 1092-1 PN40 or ANSI; Special flanges upon request | AE32 | Cold, hot and superheated water systems | DN 1", DN 25 | Female screwed ISO 7/1Rp(BS21); Flanged EN 1092 -1or ANSI; Special flanges upon request | AE30SS | Cold, hot and superheated water systems | DN ½" and ¾" | Inlet ½" or ¾" vertical; Outlet ½" vertical; Female screwed ISO 7/1Rp(BS21); ANSI B2.1 on request |
Techical datasheet : AE16 (DN15-25).pdf
| | | | |
Vacuum BreakerThe VB 21 vacuum breakers are simple and reliable devices that automatically relieve or "break" an unwanted vacuum condition, restoring the atmospheric pressure. VB 21 | | | This device is particularly suitable for steam heated units of small and medium volume as heat exchangers, heating coils, calorifiers, jacketed kettles, steam boilers, etc. |
Highlights - Use: Saturated and superheated steam
- Sizes: ½"
- Connections:
- Inlet ½" vertical
- Outlet 1/8" horizontal
- Female screwed ISO 7/1 Rp (BS21)
Techical datasheet : VB21 (DN15).pdf
| | | | |
StrainersStrainers are applicable to all types of steam, water, oil and air systems. Y Strainers | | | Their purpose is to protect traps, regulating valves, piping, etc. from dirt which are often times the cause of damage and consequently energy loss of fluid systems. |
Connections are female screwed or flanged. Model | Options | Use | Size | Connections | IS140 | Different screen aperture sizes; Drain plug or drain valve in strainer cap | Saturated steam, water, oil, air and other compatible fluids | IS 140S - DN ½" to DN 2"; IS 140I - DN ½" to DN 1" | Female screwed ISO 7/1 Rp (BS21) | IS16F | Different screen aperture sizes; Drain plug or drain valve in strainer cap | Saturated steam, water, oil, air and other compatible fluids | DN 15 to DN 300 | Flanged EN 1092-2 PN16 | IS116 | Different screen aperture sizes; Drain plug or drain valve in strainer cap | Saturated steam, water, oil, air and other compatible fluids | DN ½" to DN 2"; DN 15 to DN50 | Female screwed ISO 7/1 Rp (BS21); NPT (ANSI B1.20.1); Flanged EN 1092-1 or ANSI |
Techical datasheet : IS140 (DN15-50).pdf
| | | | |
T Strainers | | | Strainers are applicable to all types of steam, water, oil and air systems. |
T strainers are applicable to all types of steam, water, oil and air systems. Their purpose is to protect steam traps, regulating valves, pressure reducing valves, piping, etc. from dirt which are often times the cause of damage and consequently energy loss of fluid systems. Connections are flanged. Techical datasheet : IS40T (DN15-100-EN).pdf
| | | | |
Sight CheckerSight checker is a device to be used for visually checking the conditions and leakage of steam traps. SCK | | | SCK sight checker functions as both sight glass and check valve. |
Being installed after the steam trap, the sight checker is a device to be used for visually checking the conditions and leakage of steam traps. Connections are female screwed. SCK should be fitted at least 1m from the trap in order to protect the glass from thermal pressure or shock. Techical datasheet : SCK (DN15-25).pdf
| | | | |
SW and DW Series | | | Single/Double window SW sight glass for monitoring the right operation of a steam trap to avoid leakage of live steam and consequently big energy losses. |
Single/Double window SW sight glass is recommended to be installed downstream of the steam trap. Connections are female screwed or flanged. Models | Type | Use | Size | Connections | SW12 | Single Glass | Condensate pipes downstream steam traps | DN ½", 3/4" and DN 1" | Female screwed ISO 7/1Rp(BS21) | DW40S | Double Glass | Condensate pipes downstream steam traps | DN ½" to DN 1"; DN 15 to DN 25 or DN 11/4" to DN 2 "; DN 32 to DN 50 | Female screwed ISO 7/1Rp(BS21); NPT (ANSI B1.20.1); Flanged EN 1092-1 or ANSI | DW12 | Double Glass | Condensate pipes downstream steam traps | DN 11/4" to DN 2" | Female screwed ISO 7/1Rp(BS21) | DW12G - DW12SS | Double Glass | Condensate pipes downstream steam traps | DN15 to DN150 | Flanged EN 1092-1/-2 PN16-PN25 | DW16SS | Double Glass | Condensate pipes downstream steam traps | ½" to DN 1" - DN15 to DN25; 11/2" and 2" on request | Female screwed ISO 7/1Rp(BS21); NPT (ANSI B1.20.1); Flanged EN 1092-1 or ANSI (welded flanges) |
Techical datasheet : SW12 (DN15-25).pdf
| | | | |
Noise DiffuserAll stainless steel noise diffusers spread out the high velocity discharge from steam or air traps while dampening the level of noise associated with steam or compressed air trap cycles. DF 15 | | | Do not install the diffuser in such a manner that it may cause an accidental exposure to the discharge. |
Highlights - A reduction of about 80% of noise can be expected measured at 1 meter from the application
- Simple and compact design
- Connections are female screwed
Techical datasheet : DF15 (DN10-20).pdf
| | | | |
Non-Return ValvesAll non-return valves have a compact design and were specially designed for use with steam and hot condensate. RT 25 | | | Valve is designed for saturated steam, water and other gases compatible with the construction. |
Highlights - Low pressure drop
- Simple and compact design
- Connections are female screwed
- Sizes: DN ¼" to DN 2"
- Connections: Female screwed ISO 7/1 Rp (BS21)
Techical datasheet : RT25 (DN08-50).pdf
| | | | |
RD 40 | | | Valve is designed for saturated steam, water and other gases compatible with the construction. |
Highlights - Low pressure drop
- Simple and compact design
- Overall lengths according to DIN 3202 part 3-K4
- Sizes: DN 125 to DN 200
- Connections: Sandwiched between flanges as per EN 1092 or ANSI
Techical datasheet : RD40 (DN125-200).pdf
| | | | |
Globe ValveBronze in line stop valves, screwed type for use on steam, water, oil or air applications. GV 32B | | | Valve has PTFE renewable disk. Connections are female screwed ISO7/1Rp(BS21). |
Highlights - Rising stem
- Sizes: DN1/2",3/4" and 1"
- High quality PTFE packing
Techical datasheet : GV32B.pdf
| | | | |
Needle ValveA high pressure needle stop valve, designed for steam and other industrial fluids isolation. NV 400 | | | Valve has complete stainless steel construction. |
Highlights - Rising stem
- High quality graphite packing
- Sizes: DN ¼",3/8" and ½"
- Connections: Female screwed ISO7/1Rp(BS21)
Techical datasheet : NV400 (DN08-15).pdf
| | | | |
Pressure GaugesMAN-100 pressure gauges have 100 mm diameter and are marked in bar. MAN 100 | | | Pressure gauges have connections - DN ½" bottom, back eccentric. Measuring range from -1 to 40 bar. |
Highlights - Accuracy: Class 1
- Case: Stainless steel
- Lens: Glass
- Dial: Aluminium white
- Pointer: Aluminium black
- Measuring system: Copper alloy
Techical datasheet : MAN-Pressure Gauge.pdf
| | | | |
Other products from this manufacturer |