Mass FlowmetersWhen it comes to Coriolis mass flowmeters, excellent measuring technology should not be a question of budget. That's why KROHNE'S engineers have developed the cost-effective devices, the OPTIMASS, with a whole series of features normally reserved for high-tech devices. Lai iegūtu vairāk informācijas, veiciet nospiedienu uz attēla vai produkta virsraksta. Detalizētu informāciju par izvēlēto produktu jūs varat iegūt, lejupielādējot tehniskās dokumentācijas failu. Choose the flowmeter that best matches your application from the following table. Further details are contained on this page below, and in the data sheets available for download. Legend: Suitable
Application | OPTIMASS | OPTIGAS 5010C | OPTIBATCH 4011C | MFC 300 | MFC 010 | 1000 | 2000 | 3000 | 7000 | 8000K | Hygienic processes: Brewing | Meassurement of flow, density, specific gravity | | | | | | | | | | CO2 Injection | | | | | | | | | | Dosing of hop extract | | | | | | | | | | Hygienic processes: Food | Measurement of flow, density, content dosing of yoghurt, fruit and oil | | | | | | | | | | Hygienic processes: Fruit juice | Measurement of BRIX, density, flow | | | | | | | | | | Hygienic processes: Production | Dosing of additive components | | | | | | | | | | Batching, dosing, filling | | | | | | | | | | Pharmaceutical Industry | Batching, dosing, filling | | | | | | | | | | Solvent extraction | | | | | | | | | | Ultra pure-water ring-main measurement | | | | | | | | | | Oil & Gas Industry | Metering Skids | | | | | | | | | | Bypass density measurement | | | | | | | | | | CNG/LPG Despensers | | | | | | | | | | Bulk loading | | | | | | | | | | Pipeline transfer | | | | | | | | | | In-line density | | | | | | | | | | Mining, Machinery, Minerals | Abrasive sludge/ slurries | | | | | | | | | | Water / Waste water | Floccul and dosing | | | | | | | | | | Sludge flow and density measurement | | | | | | | | | | Chemical Industry | Measurement of concentration, density | | | | | | | | | | Bulk loading | | | | | | | | | | Batching to reactores | | | | | | | | | | Hydrocarbon cracking | | | | | | | | | | Paper and Pulp | Paperstock, pulp | | | | | | | | | | Additives, bleaches, colourants | | | | | | | | | |
Mass FlowmetersThe function of mass flowmeters is based on the Coriolis principle. They allow for a direct measurement of mass flow, density and temperature of liquids and gases as well as calculation of volume flow and mass or volume concentration with a single device. OPTIMASS 1000 | | | The OPTIMASS 1000 is the cost effective solution for accurate measurement for a variety of applications. The OPTIMASS 1000 reliably measures massflow, density, volume, temperature, volume concentration or solid content. |
Highlights - Innovative twin measuring tubes
- Easily drained and easy to clean
- Resistant to installation and process effects
- Long working life
- Optimised flow divider for minimum pressure loss
- High levels of accuracy means an excellent price / performance ratio
- Modular electronics with data redundancy - "plug & play" replacement of electronics
Nozares - Water & wastewater
- Chemical
- Food & beverage
- Paper & pulp
- Petrochemical industry
- Pharmaceutical industry
Applications - Suitable for all standard applications up to 130°C
- Hygienic connections make it ideal for food / beverage applications
Tehnisko datu fails : OPTIMASS 1000.pdf
| | | | |
OPTIMASS 2000 | | | The OPTIMASS 2000 has been developed to meet the demanding custody transfer requirements of the oil and gas industry, it is well suited to bulk measurement in many applications. |
Highlights - Innovative twin measuring tube design with large tube size, provide high flow rate capacity
- Easily drained and easy to clean
- Optional heating jacket
- High accuracy for custody transfer
- Optimised flow divider for minimum pressure loss
- Modular electronics concept: electronics and sensor are easy to replace
- Super Duplex option for operating pressures up to 180 barg
- Secondary containment up to 150 barg
Nozares - Oil & Gas
- Waste Water
- Chemical
- Paper & Pulp
- Food & Beverage
- Pharmaceutical
- Fresh Water
Applications - Bulk loading/unloading
- Custody transfer for volume and mass
- High Volume
Tehnisko datu fails : OPTIMASS 2000.pdf
| | | | |
OPTIMASS 3000 | | | The OPTIMASS 3000 is the cost effective solution for accurate measurement in a variety of applications, where there is a low process flow. |
Highlights - Z-shaped measuring tube
- Easily drained and easy to clean
- Optional heating jacket
- Simple installation and start-up
- Modular electronics concept - electronics and sensor are easy to replace
- Data redundancy - accurate plug & play replacement of electronics
Nozares - Wastewater
- Chemical
- Food & Beverage
- Paper & pulp
- Pharmaceutical
- Automotive
Applications - Fragrance dispensing and high precision coatings in the pharmaceutical industry
- CO2 injection and dosing in the food and beverage industry
- Natural gas and propane odorisation
- Engine test beds in the automotive industry
Tehnisko datu fails : OPTIMASS 3000.pdf
| | | | |
OPTIMASS 7000 | | | The OPTIMASS 7000 is the only sensor for mass flow with a single straight measuring tube that is available in titanium, stainless steel, hastelloy or tantalum. |
Highlights - Outer cylinder typical burst pressure greater than 100 barg / 1450 psig, with optional PED approved secondary pressure containment available
- Easily drained and easy to clean
- Resistant to installation and process effects
- Excellent zero stability
- Low energy consumption, means lower operating costs
- Rapid signal processing, even with product / temperature changes
- Modular electronics with data redundancy - "plug & play" replacement of electronics
Nozares - Water & wastewater
- Mining & building materials
- Iron, steel and metal processing
- Food & beverage
- Oil, gas and alternative fuels
- Paper & pulp
- Petrochemical industry
- Pharmaceutical industry
- Chemical industry
Applications - Viscous or shear-sensitive products
- Products requiring low flow velocities
- Non-homogeneous mixtures
- Products with entrained solids or gas
- Custody transfer
- Loading and product transfer measurement
- Slurries
- Highly corrosive fluids
Tehnisko datu fails : OPTIMASS 7000.pdf
| | | | |
OPTIMASS 8000 K | | | A high level of performance, together with a wide operating temperature range up to 230°C, makes the OPTIMASS 8000k the ideal choice for mass flow measurement in a wide variety of applications. |
Highlights - Innovative twin U-tube design
- Temperature range -195°C to +230°C
- Optional insulation / heating jacket
- Compact envelope
- Optimised flow divider for minimum pressure loss
- Modular electronics concept: electronics and sensor are easy to replace
- Self draining when mounted vertically
Nozares - Fresh and waste water
- Chemical
- Oil and gas
- Food and beverage
- Pharmaceutical
- Fresh Water
- General industry
- Supercritical gases
Applications - Crystallising, solidifying and cryogenic products
- Tanker loading
- General purpose applications
- CIP and SIP >130°C
- Liquid Natural Gas (LNG)
Tehnisko datu fails : OPTIMASS 8000k.pdf
| | | | |
OPTIGAS 5010 C | | | Mass flowmeter for compressed natural gas (CNG) and liquefied petroleum gas (LPG) dispensers. |
Highlights - Two sizes: S 15 (50 kg/min flow) or S 25 (120 kg/min)
- Signal converter (transmitter)or MODBUS Direct Data Communication DDC outputs
- High accuracy and wide measuring range
- Compact and low cost
- Easy to install and commision
- Developed in conjunction with dispenser manufacturers
Tehnisko datu fails : OPTIGAS 5010C.pdf
| | | | |
OPTIBATCH 4011 C | | | The OPTIBATCH has been developed to compliment the OPTIMASS family of mass flowmeters, as a specialised meter for batching and filling machines. |
Highlights - Compact design
- Integrated electronics
- Excellent reliability and accuracy
- Hygienic design of process connections
- Excellent repeatability
- Stainless Steel 316L construction
- CIP / SIP to maximum 120ºC / 248ºF
- Welded outer casing, sealed to IP 67
Nozares - Food & Beverages
- Chemical
- Pharmaceutical industry
- Cosmetics
- Health Care
Applications - Filling machines
- Fast batching
- Ultra-pure water
Tehnisko datu fails : OPTIBATCH 4011.pdf
| | | | |
MFC 300 | | | The MFC 300 is a universal Coriolis mass flow signal converter suitable for a wide range of applications and installations. The common platform for the modular hardware allows easy selection for the required output options, and is suitable for mounting in various housing configurations. |
Highlights - Modular versions from a basic signal converter to a high-end option with multiple output options
- Advanced diagnostic functions
- Excellent long term stability
- Easy to install and program due to improved user interface
- Maximum process safety
- Tropicalised and Stainless Steel versions for harsh environmental conditions
Nozares - Water & Wastewater
- Chemicals
- Elektrostacijas
- Food & Beverage
- Machinery
- Oil & Gas
- Petrochemicals
- Pulp & Paper
- Pharmaceutical
Applications - Liquids and gases
- Slurries and viscous products
- Concentration measurement for quality control
- Measurement of volume flow
- Measurement of density and reference density
- Custody transfer loading/unloading
- Custody transfer measurements
Tehnisko datu fails : MFC 300.pdf
| | | | |
MFC 010 | | | The MFC 010 mass flowmeter implements all sensor drive and signal evaluation functions into an integrated front-end electronics module permanently fixed to the sensor. |
Highlights - Modbus communication direct from meter; no need for separate converter
- Connection using standard, off-the-shelf, four-core cable
- Cost effective solution since no converter needed
- Applicable for Ex and non-Ex installation
- Full functionality through using Modbus communication: all measured variables, ability to program meter, sensor and process diagnostics
- Full range of OPTIMASS sensor types and OPTIGAS
- Full range of sensor materials, connections and options available
Tehnisko datu fails : MFC 010.pdf
| | | | |
Citi šī ražotāja produkti |