Other Flowmeters and ControlersKROHNE vortex flowmeters work on the vortex shedding principle, are globally accepted as the world standard in measurement of liquid, steam and gas flow. With the flow controllers DW 181, 182, 183 and 184, KROHNE offers the ideal flow control solution for virtually any process connection. To get more information please expand the product block by pressing on image or product title. To get detailed information about specific product you can download Technical datasheet file by clicking corresponding link. Vortex FlowmetersSuitable for a wide range of media. KROHNE Vortex Flowmeters work on the vortex shedding principle, are globally accepted as the world standard in measurement of liquid, steam and gas flow. OPTISWIRL 4070 | | | The first vortex flowmeter to feature integrated pressure and temperature compensation in 2-wire technology. |
Highlights - 2-wire device with integrated pressure and temperature compensation
- Non-wearing, fully welded stainless steel construction with high corrosion, pressure and temperature resistance
- Optimal process reliability thanks to Intelligent Signal Processing (ISP) - stable readings, free of external perturbations
- Ready to use immediately thanks to plug & play
- Maintenance-free measuring sensor design
- PACTware available at no extra cost
- Pressure and temperature available via HART
Valdkonnad - Chemicals
- Oil & Gas
- Power plants
- Food & Beverage
- Pharmaceuticals
- Iron, Steel and Metals
- Paper and pulp
- Water
- Automobile industry
Applications - Vapour and saturated steam measurement
- Steam boiler monitoring
- Monitoring of compressor output
- Measurement of consumption in compressed air systems
- Measurement of consumption of industrial gases
- SIP and CIP processes in the food, beverage and pharmaceutical industries
- Measurement of conductive and non-conductive liquids
Techical datasheet : OPTISWIRL 4070.pdf
| | | | |
Flow ControllersBased on Faraday's law of induction, electromagnetic flow controllers monitor or measure the flow speed of electrically conductive liquids. DWM 1000, DWM 2000 | | | With the DWM 1000 and DWM 2000 flow controllers, KROHNE offers its customers two sturdy units. |
Highlights - DIP switch for setting full-scale value
- Zero calibration button removes zero drift
- Long version available for pipes larger than 400 mm / 16" in diameter
- Optional ball valve for long version
- Rugged design, IP66 (NEMA 4/4X) protection
- IP 68 version available for immersed applications
- Suitable for process temperatures up to 150°C / 300°F and process pressures up to 25 bar / 360 psig
- Optional digital display for DWM 2000 meters
- Suitable for AC and DC electrical circuits (relays available for the DWM 1000)
- Optional spool pieces for pipe diameters DN25...50 or 1"...2"
- Optional fitting for Tuchenhagen VARIVENT® housings
- Housing is removable or rotatable under process conditions
Valdkonnad - Petrochemical
- Oil & Gas
- Chemical
- Food & beverage
- Water
- Air conditioning (HVAC)
Applications - Flow detection
- Cooling systems
- Pump protection
Techical datasheet : DWM1000,2000.pdf
| | | | |
DW 181 | | | The DW 181 inline flow controller is suitable for horizontal or vertical pipes. It can have G or NPT threaded connections, sizes ranging from ¾...2". |
The measuring tube and connection are made of either bronze or 316 L (1.4404) stainless steel. There are two types of indicator available for this variant: - a linear scale with up to two alarm positions at the top and bottom of the indicator
- a dial which has been made specifically for this instrument and tested on a calibration rig
Highlights - Permanent readings using a powerful magnet
- No need for a power supply to indicate flow
- Unique Ex d design (without dial for local readings)
- High temperature version (without local indication) can operate up to 300°C (570°F)
- Available for process pressures up to 120 bar (1740 psig)
- No pipe diameter limit: Insertion-type version is suitable for pipes >250mm
- Any tube length is available for easy replacement of existing units
- Large choice of process connections and wetted parts material
- With optional stainless steel housing
- Works with any clean liquid in any position
- High reliability and repeatability
- Alarm position: set by factory free of charge during test rig flow calibration
- Each instrument is individually calibrated and tested
- Switch value can be dry-tested!
- Optional 3-wire device (without local indication) with 4-20 mA current output (not CE certified!)
- Power supply device and digital indication possible via C95 Ci or similar
Valdkonnad - Petrochemical
- Oil & Gas
- Chemical
- Water
- Air-conditioning (HVAC)
Applications - Flow detection
- Cooling systems
- Pump protection
- Lubrication control
- Cavitation alarm
Techical datasheet : DW181,182,183,184.pdf
| | | | |
DW 182 | | | The DW 182 inline flow controller is suitable for horizontal or vertical pipes. It has flanged connections, sizes ranging from DN 15...DN 65 or from ½...2½". |
The measuring tube and connection is made of 316 L (1.4404) stainless steel. There are two types of indicator available for this variant: - a linear scale with up to two alarm positions at the top and bottom of the indicator
- a dial (as shown) which has been made specifically for the instrument and tested on a calibration rig
Highlights - Permanent readings using a powerful magnet
- No need for a power supply to indicate flow
- Unique Ex d design (without dial for local readings)
- High temperature version (without local indication) can operate up to 300°C (570°F)
- Available for process pressures up to 120 bar (1740 psig)
- No pipe diameter limit: Insertion-type version is suitable for pipes >250mm
- Any tube length is available for easy replacement of existing units
- Large choice of process connections and wetted parts material
- With optional stainless steel housing
- Works with any clean liquid in any position
- High reliability and repeatability
- Alarm position: set by factory free of charge during test rig flow calibration
- Each instrument is individually calibrated and tested
- Switch value can be dry-tested!
- Optional 3-wire device (without local indication) with 4-20 mA current output (not CE certified!)
- Power supply device and digital indication possible via C95 Ci or similar
Valdkonnad - Petrochemical
- Oil & Gas
- Chemical
- Water
- Air-conditioning (HVAC)
Applications - Flow detection
- Cooling systems
- Pump protection
- Lubrication control
- Cavitation alarm
Techical datasheet : DW181,182,183,184.pdf
| | | | |
DW 183 | | | The DW 183 inline flow controller is suitable for horizontal or vertical pipes. It has flanged connections, sizes ranging from DN 65...DN 200 and 2½...8". |
The measuring tube and connection is made of either XC 18 (1020) carbon steel or 316 L (1.4404) stainless steel. Carbon steel flanges with nominal diameters bigger than 100 or 4" can have 316 L stainless steel cladding. There are two types of indicator available for this variant: - a linear scale with up to two alarm positions at the top and bottom of the indicator
- a dial (as shown) which has been made specifically for this instrument and tested on a calibration rig
Highlights - Permanent readings using a powerful magnet
- No need for a power supply to indicate flow
- Unique Ex d design (without dial for local readings)
- High temperature version (without local indication) can operate up to 300°C (570°F)
- Available for process pressures up to 120 bar (1740 psig)
- No pipe diameter limit: Insertion-type version is suitable for pipes >250mm
- Any tube length is available for easy replacement of existing units
- Large choice of process connections and wetted parts material
- With optional stainless steel housing
- Works with any clean liquid in any position
- High reliability and repeatability
- Alarm position: set by factory free of charge during test rig flow calibration
- Each instrument is individually calibrated and tested
- Switch value can be dry-tested!
- Optional 3-wire device (without local indication) with 4-20 mA current output (not CE certified!)
- Power supply device and digital indication possible via C95 Ci or similar
Valdkonnad - Petrochemical
- Oil & Gas
- Chemical
- Water
- Air-conditioning (HVAC)
Applications - Flow detection
- Cooling systems
- Pump protection
- Lubrication control
- Cavitation alarm
Techical datasheet : DW181,182,183,184.pdf
| | | | |
DW 184 | | | The DW 184 insertion-type flow controller checks flow velocity. It is suitable for horizontal and vertical pipes with nominal diameters of 250 mm / 10" or bigger - there is no maximum pipe diameter. |
It is installed on a DN 150 PN 16/40 or 6" ASME150/300 lbs mounting flange. The measuring tube and connection is made of either 1020 (XC 18) carbon steel or 316 L (1.4404) stainless steel. A mounting flange made of carbon steel can also have 316 L stainless steel cladding. One type of indicator is available for this variant: - a linear scale with alarm positions at the top and bottom of the indicator
Highlights - Permanent readings using a powerful magnet
- No need for a power supply to indicate flow
- Unique Ex d design (without dial for local readings)
- High temperature version (without local indication) can operate up to 300°C (570°F)
- Available for process pressures up to 120 bar (1740 psig)
- No pipe diameter limit: Insertion-type version is suitable for pipes >250mm
- Any tube length is available for easy replacement of existing units
- Large choice of process connections and wetted parts material
- With optional stainless steel housing
- Works with any clean liquid in any position
- High reliability and repeatability
- Alarm position: set by factory free of charge during test rig flow calibration
- Each instrument is individually calibrated and tested
- Switch value can be dry-tested!
- Optional 3-wire device (without local indication) with 4-20 mA current output (not CE certified!)
- Power supply device and digital indication possible via C95 Ci or similar
Valdkonnad - Petrochemical
- Oil & Gas
- Chemical
- Water
- Air-conditioning (HVAC)
Applications - Flow detection
- Cooling systems
- Pump protection
- Lubrication control
- Cavitation alarm
Techical datasheet : DW181,182,183,184.pdf
| | | | |
SDA | | | The SDA flap-type flowmeter can be used for flowmetering various kinds of liquid products. |
Flap-type flowmeter for liquid measurements - The SDA flap-type flowmeter can be used for flowmetering various kinds of liquid products by using different materials of construction and different mounting positions. The flowmeter is largely independent of viscosity and suitable for indicating the flow of water, acids and alkalis.
Highlights - Universal flap-type flowmeter
- Mounting position: horizontal, vertical
- Low pressure drop
- Largely independent of viscosity
Techical datasheet : SDA.pdf
| | | | |
Other products from this manufacturer |