Special EquipmentThis group of items is perhaps the most atypical. It consists of different equipment and, in most cases, specially developed to process industries. To get more information please expand the product block by pressing on image or product title. To get detailed information about specific product you can download Technical datasheet file by clicking corresponding link. Pressure Operated PumpThe ADCAMAT POP (Pressure Operated Pump) fabricated carbon steel (stainless steel on request) is recommended in the transfer of high-temperature liquids such as condensate, oils and other liquids to a higher elevation or pressure. ADCAMAT POP | | | The pump can be operated by steam, compressed air or gas and can be used for lifting any kind of no corrosive liquids. |
Connections are flanged or female screwed (with screwed flanges). Operation - Liquid flows by gravity into the pump through an inlet check valve lifting a float which, at the upper limit of its travel, opens the supply valve which allows steam or compressed air to enter the pump body. Pressure in the pump builds up until just sufficient to overcome back pressure.
- The pressurized liquid opens the outlet check valve and discharge commences. When the float reaches the minimum lower level it closes the steam or compressed air supply valve and opens the vent, allowing the liquid to fill the pump again.
- As the amount of liquid discharged at each stroke is known, the total volume passed during a given period can be calculated by counting the number of strokes during that period. For this purpose a special counter is available which screws into a tapped connection on the top cover of the pump. This counter records the number of pumping strokes thus enabling the pump to function as a reliable flow meter.
Models | Options | Use | Size | Connections | ADCAMAT POP-S (DN25-80) | Stainless steel construction; Level gauge; Stroke counter | To lift condensate or hot and cold liquids | DN 25; DN 40; DN 50; DN 80x50 | Flanged EN1092-1 PN16; Special flanges upon request; Female screwed ISO 7/1 Rp (BS21) | ADCAMAT POP-S (DN100) | Duplex packaged design; Stainless steel construction; Level gauge; Stroke counter | To lift condensate or hot and cold liquids | DN 100x100 | Flanged EN1092-1 PN16; Special flanges upon request; Female screwed ISO 7/1 Rp (BS21) | ADCAMAT POP LC | Non-electric requirements; Pump mechanism can be installed in any position rotating 360°, only limited by the flange holes | To lift condensate or hot and cold liquids | DN 25 LC; DN 40 LC; DN 40x25 LC | Flanged EN1092-1 PN16; Special flanges upon request; Female screwed ISO 7/1 Rp (BS21) | ADCAMAT PPO-14 | Stainless steel construction; Level gauge. Stroke counter; To lift condensate or hot and cold liquids | To lift condensate or hot and cold liquids | DN 25; DN 40; DN 50 | Flanged EN1092-1 PN16; Special flanges upon request; Female screwed ISO 7/1 Rp (BS21) |
To get information about how to select and size POP and PPO download "POP,PPO - Select And Size" data sheet. Techical datasheet : POP,PPO - Select And Size.pdf
| | | | |
DeaeratorsAdcatherm thermal deaerators are designed to heat boiler feed water and to reduce oxygen and carbon dioxide. ADG | | | Oxygen values in the feed water of less than 1,6mg/l, can be achieved. |
Remaining oxygen can be completely removed using oxygen scavenging chemicals. Basically the complete system consists of a storage vessel, a deaeration head section and a vent. Highlights - Prevents energy wasting
- Easy to install
- Can be installed on new or existing systems
- Reduces the flow of flash steam from the vessel venting pipe
- Long life expectancy
Techical datasheet : Adcatherm ADG.pdf
| | | | |
TDG | | | Oxygen values in the feed water of less than 0,02mg/l - 0,02 ppm, can be achieved. |
Remaining oxygen can be completely removed using oxygen scavenging chemicals. Basically the complete system consists of a storage vessel, a deaeration section and a vent. Highlights - Turndown (max./min flow) - 100:1
- Long life expectancy
Techical datasheet : Adcatherm TDG.pdf
| | | | |
Steam Distribution And Control SystemsFor effiecient and predictable steam flow, Valsteam offers distribution manifold, flash condensing heads, blowdown and cooling units, lifting pots and valves. MAS | | | MAS series steam distribution manifolds place the steam supply valves in one location, providing cost savings and easy control of different steam lines. |
The drain connection with automatic steam trap, discharge any condensate formed, providing high quality dry steam. Highlights - Several installation possibilities
- Reduced field assembly costs by means of prefabrication
Techical datasheet : MAS Steam distribution manifold.pdf
| | | | |
FCD | | | Mixing the flash steam with the boiler water make up allows the energy within the flash steam to be fully absorbed into the water and therefore reduces energy waste that normally occurs from the discharge of flash steam through a vent. |
The main advantages over some traditional systems are that it is possible to make most of the piping connections in a single and compact mixing unit and that a greater quantity of heat recovery can be achieved. Highlights - Prevents energy wasting
- Easy to install
- Stainless steel construction
- Reduces the flow of flash steam from the vessel venting pipe
Techical datasheet : Adcatherm FCD Flash condensing heads.pdf
| | | | |
BEX | | | The waste water is discharged into the unit which is at atmospheric pressure and the cooling water enters via a control valve controlled by a thermostat, mixing with the hot water. |
Highlights - Prevents thermal pollution
- Overflow with siphon breaker
- Easy to install
- Reduces the flow of flash steam
Techical datasheet : BEX.pdf
| | | | |
LIPO | | | LIPO condensate lifting pots are used for rising condensate pipes eliminating steam and water hammering. |
Operation - When the condensate is elevated to the condensate main in a higher level the flash steam that is formed after a steam trap when in contact with colder condensate condenses and steam bubbles implode, reducing its volume when passing to the liquid state. Vacuum is then formed suddenly which is filled again by incoming condensate causing water hammer.
- The air and flash steam cushion formed in the upper part of the lifting pot absorb any chock while in the bottom the condensate operates as a sealing liquid.
Techical datasheet : LIPO Lifting pot.pdf
| | | | |
MX 20 | | | The steam/water Adcamix mixers provide cheap, instant source of low pressure hot water by using existing steam and cold water supplies. |
Highlights - Safety device against accidentally steam ejection
- Non return valves included
- Complete stainless steel construction
- Quiet operation
Techical datasheet : MX20 Adcamix.pdf
| | | | |
Heat ExchangersThe ADCA steam to water shell and tube heat exchangers are shorter and lighter than the alternative shell and tube exchangers manufactured with smooth pipes. Adcatherm STS, STH, STV | | | The use of extruded low fin tube has the advantage that it can improve the external surface and thermal performance. |
Highlights - Corrosion-resistant stainless steel low finned tube bundle and shell construction
- Straight tubes for easy cleaning
- Expansion bellow in the shell avoiding excessive tube stresses caused by thermal expansion and contraction
Models | Options | Use | Connections | Installation | Adcatherm - STS Type | Horizontal installation | Steam, water, hot condensate and other fluids compatible with the construction | - | Vertical or horizontal (different condensate heads execution) | Adcatherm - STH Type | Vertical installation | Steam, water, hot condensate and other fluids compatible with the construction | Flanged or screwed, according to EN 1092-1 or ANSI standards | Floor, wall, hanging from the ceiling; Steam runs inside the tubes and process water outside | Adcatherm - STV Type | Horizontal installation | Steam, water, hot condensate and other fluids compatible with the construction | Flanged or screwed, according to EN 1092-1 or ANSI standards | Wall mounting or floor with special supports; Steam runs inside the tubes and process water outside |
Techical datasheet : Adcatherm - STS.pdf
| | | | |
Heating CoilsThe ADCA-R series steam to water tubular heating coils are shorter and lighter than the alternative tubular heating coils manufactured with smooth pipes. The use of extruded low fin tube, has the advantage that it can improve the external surface and thermal performance. R Series | | | Corrosion-resistant stainless steel low finned tube bundle construction. |
Highlights - Straight tubes for easy cleaning
- Floating head at the end of the tube bundle, avoiding tube stresses caused by thermal expansion and contraction
Techical datasheet : Adcatherm R - Heating Coils.pdf
| | | | |
SeparatorsCentrifugal separators remove moisture from steam and compressed air pipelines. S Series | | | Steam and compressed air passing through the separator and as a result of centrifugal forces, impact and swirling effects, separate the particles with a heavier specific gravity, such as water and oil droplets, moisture in suspension, dirt and scale. |
The condensate collected at the bottom of the separator, must be automatically drained by a suitable steam or compressed air trap. Connections are threaded. Models | Options | Use | Size | Connections | S16S | Zinc plated (compressed air); Condensate flanged connection | Steam, compressed air and other gases | DN ½" to DN 2" | Screwed BSP or NPT | S25S | Zinc plated (compressed air); Condensate flanged connection | Steam, compressed air and other gases | DN15 to DN300 | Flanged EN1092-1 PN16 and PN40; ANSI Class 150 lbs and Class 300 lbs; Female screwed BSP or NPT on request | Zinc plated fabricated carbon steel construction (compressed air); Condensate flanged connection | Steam, compressed air and other gases | DN15 to DN200 | Flanged EN1092-1 PN 63; ANSI Class 600 lbs; SW - Socket weld to ANSI B 16.11 | S25S HV/VH | Zinc plated fabricated carbon steel construction (compressed air); Condensate flanged connection | Steam, compressed air and other gases | DN15 to DN200 | Flanged EN1092-1 PN16 and PN40; ANSI Class 150 lbs and Class 300 lbs; Female screwed BSP or NPT on request | S25SS | Condensate flanged connection | Steam, compressed air and other gases | DN15 to DN300 | Flanged EN1092-1 PN16 and PN40; ANSI Class 150 lbs and Class 300 lbs; Female screwed BSP or NPT on request |
Techical datasheet : S16S (PN16 DN15-50).pdf
| | | | |
AS - AS/F | | | The AS centrifugal air and dirt separators are designed for use in the flow line of a hydronic heater or cooling system. |
The operation is based on the principle of centrifugal force, instead of relying on low velocity separation, offering the advantage of efficient separation in a smaller vessel. Highlights - Galvanised and complete stainless steel construction
- Sizes:
- Screwed: DN11/4" to DN2"
- Flanged: DN32 to DN300
- Connections:
- Female screwed ISO 7/1Rp(BS21)
- Flanged EN 1092-1 or ANSI
Techical datasheet : AS (DN32-300).pdf
| | | | |
S252/F | | | S-252/F series centrifugal separators remove moisture from steam and compressed air pipelines. |
Highlights - Several possibilities of installation
- No moving parts
- Stainless steel strainer screen included
Techical datasheet : S252F (PN16-PN40 DN15-300).pdf
| | | | |
SH25S | | | Steam and compressed air passing through the separator and as a result of centrifugal forces, impact and swirling effects, separate the particles with a heavier specific gravity, such as water and oil droplets, moisture in suspension, dirt and scale. |
Connections are threaded or flanged. Highligts - In-line design
- No moving parts
- Sizes: DN15 to DN100
- Connections:
- Flanged EN1092-1 PN16 and PN40
- ANSI Class 150 lbs and Class 300 lbs
- Female screwed BSP or NPT on request
Techical datasheet : SH25S (PN16-PN40 DN15-100).pdf
| | | | |
Exhaust HeadsThe EH Exhaust Head is designed to protect the personnel from injury and exterior of buildings from the harmful effects of steam ejection to atmosphere. EH | | | The head is fitted to the end of a vertical exhaust pipe and thus breaks the beat and muffles the noise of escaping steam whilst effectively retaining the moisture for draining. |
Highlights - Stainless steel separating element
- Quite operation
- Reduces discharge velocity
Techical datasheet : EH.pdf
| | | | |
Flash VesselsThe flash vessel is the main component in any flash recovery system. It can be used in all steam plants where high pressure condensate is reduced to a lower pressure, so that flash steam is formed by re-evaporation. RV | | | This steam can be used in low pressure process or heating equipments. Connections are flanged or screwed on request.] |
Highlights - Complete stainless steel construction
- Sizes: RV06, RV08, RV12, RV16 and RV18
- Several possibilities of installation and special sizes and types (available on request)
Techical datasheet : Flash Vessels.pdf
| | | | |
Steam InjectorsSteam injectors from ADCA are injection condensers. They ensure low noise and vibration and rapid heating of still or flowing fluids in basins and vessels due to direct steam injection. SI Series | | | Steam enters through the inlet housing, passes along the centre of the heater, through holes in the inner rings, through spaces between the element plates where it condensates under light load and partly condensates under heavy load to be discharged through the serrated periphery of the element plates. |
Highlights - Quiet operation
- Corrosion-resistant
- No moving parts
Models | Options | Use | Size | Connections | SI 20 | Complete system including vacuum breaker and self operated controller; Different capacities and design available under request | Direct steam injection heating systems | 3/4" | Female screwed ISO 7/1 Rp (BS21) | SI 115 | Complete system including vacuum breaker and self operated controller; Different capacities and design available under request | Direct steam injection heating systems | 1/2" | Female screwed ISO 7/1 Rp (BS21) | SI 125 - SI 140 | Complete system including vacuum breaker and self operated controller; Different capacities and design available under request | Direct steam injection heating systems | DN 1" and DN 11/2" | Female screwed ISO 7/1 Rp (BS21) |
Techical datasheet : SI-20 (DN20).pdf
| | | | |
DSH Series | | | The DSH direct steam injector humidifiers assure highly efficient steam release into the air stream. |
Each humidifier is designed for your specific capacity, steam pressure and duct width requirements. Single and multiple injection tube units are available to meet the most demanding applications. Highlights - Complete stainless steel injection tube and separator construction
- Quiet operation
Techical datasheet : DSH Direct steam injection humidifiers.pdf
| | | | |
Sample CoolersADCA sample coolers are specially designed to cool samples of boiler water or steam for analysis. SC Series | | | Sample coolers prevent steam flashing-off from hot pressurised liquid samples, which can be dangerous and will result in an incorrect water sample. |
This device may be used for boiler water analysis and other sampling or cooling applications compatible with construction materials. Highlights - Corrosion-resistant body and internals
- Self draining sample (inlet top, outlet bottom)
Models | Options | Use | Size And Connections | SC32- SC132 | Sample inlet valve; Cooling water inlet valve; Temperature indicator; Bolted top plate; Different connection sizes and materials under request against extra price; Double coil high pressure design for larger capacities | Steam boilers and hot water systems | Cooling water inlet/outlet: 1/2" on body (BSP or NPT); Sample tube inlet/outlet: 8 mm O/D | SC 32F- SC 132F | Sample inlet valve; Cooling water inlet valve; Temperature indicator; Compression fittings; Bolted top plate; Different connection sizes and materials under request against extra price | Steam boilers; Hot water systems | Cooling water body inlet 1/2", outlet ¾" (BSP or NPT); Sample tube inlet/outlet: 8 mm O/D | SC 32B- SC 132B | Sample inlet valve; Cooling water inlet valve; Temperature indicator; Compression fittings; Different connection sizes and materials under request against extra price | Steam boilers; Hot water systems | Cooling water body inlet 1/2", outlet 1/2" (BSP or NPT); Sample tube inlet/outlet: 8 mm O/D | SC332- SC532 | Sample inlet valve; Cooling water inlet valve; Temperature indicator; Bolted top plate; Different connection sizes and materials under request against extra price | Steam boilers and hot water systems | SC332 and SC332H: Cooling water inlet/outlet: 1/2" (BSP or NPT); Sample tube inlet/outlet: 10 mm O/D; SC432 and SC532; SC432H and SC532H: Cooling water inlet/outlet: 3/4" (BSP or NPT); Sample tube inlet/outlet: 10 mm O/D |
Techical datasheet : SC32-132.pdf
| | | | |
Other products from this manufacturer |